1.3KW Digital Generator Inverter System
1. Output power 2KW 2. Voltage Stabilization≤6V 3. Output Voltage: 120V/230V 4. Output Wave: Sine Wave 5. Wave Distrotion: Without loading ≤ 0.6%, with loading≤1....
-
-
2.HJ70 DC CDI
Main technical specification 1, Continuous Ignition R. Speed (r/min): 200 r/min ~ 12000 r/min 2, feature angle range: 0º/2000r/min ~ 20°/3740r/min 3, Operating Temperature Range: -20º C~ +60º C 4, Store Temperature Range: -20℃~ +80º C 5, Availible model: HJ70 DC Power
-
-
3.Motorcycle starter relay
Available Model: 70,90,100,CG125,CB125 etc. Motorcycle.low control current requested, which is less than 4A and the range for contact current is 50A to 150A .Good function on water-proof with long life.
-
-
4.Motorcycle starter relay
Available Model: 70,90,100,CG125,CB125 etc. Motorcycle.low control current requested, which is less than 4A and the range for contact current is 50A to 150A .Good function on water-proof with long life.
-
-
5.ATV starter relay
Available Model: CB150, CG150, CG250, CB250, etc. Motorcycle or ATV。low control current requested, which is less than 4A and the range for contact current is 80A to 200A。Good function on water-proof.
-
-
6.ATV starter relay
Available Model: CB150, CG150, CG250, CB250, etc. Motorcycle or ATV。low control current requested, which is less than 4A and the range for contact current is 80A to 200A。Good function on water-proof.
-
-
7.053A0 CDI
1.Min.Continuous Ignition R. Speed is less than 200r/min 2.Continuous Operating R.Speed is 200-10500r/min 3.AC Power, Steady with Strong Anti-interference Ability 4.125 DC Supply Model Availible
-
-
8.Motorcycle Starter Relay
Available Model: 90, 100, CG125, CB125, etc. low control current requested, which is less than 4A and the range for contact current is 50A to 150A Good function on water-proof and long time using.
-
-
9.Generator Inverter
1. Output power 2KW 2. Voltage Stabilization≤6V 3. Output Voltage: 120V/230V 4. Output Wave: Sine Wave 5. Wave Distrotion: Without loading ≤ 0.6%, with loading≤1.6% Magneto Output Voltage: 1. 3 Phase, 460V, 950W/1.9KW 2. Single Phase 12V, 8A 3. Direct Current: DC12V 50W/100W 4. Rated R. Speed: 4500rpm
-
-
10.3-5KW Range Regulator
1. Operating Temperature Range: (-20-80)℃ 2. Storage Temperature Range: (-40-100)℃ 3. Factory set: 25℃±5℃ Electric Index 1. Voltage: 230&...
-
-
11.1-3KW Range Regulator
Operating Condition 1. Operating Temperature Range: (-20~80)℃ 2. Storage Temperature Range: (-40~100)℃ 3. Factory set: 25℃±5℃ Electric In...
-
-
12.5-7KW Range Regulator
Operating Condition 1. Operating Temperature Range: (-20~80)℃ 2. Storage Temperature Range: (-40~100)℃ 3. Factory set: 25℃±5℃ Electric...
-
-
13.3-5KW Range Regulator
Operating Condition 1. Operating Temperature Range: (-20~80)℃ 2. Storage Temperature Range: (-40~100)℃ 3. Factory set: 25℃±5℃ Electric In...
-
-
14.152F Igniter (Mitsubishi)
`1. Operating Temperature Range: (-30~105)℃ 2. Storage Temperature Range: (-40~120)℃ 3. Operating R.Speed: 420~4200rpm 4. Fly Wheel Magnetic Field Intensity: 1500~1900GS ...
-
-
15.1P65 Igniter
`1. Operating Temperature Range: (-30~105)℃ 2. Storage Temperature Range: (-40~120)℃ 3. Operating R.Speed: 300~4200rpm 4. Fly Wheel Magnetic Field Intensity: 1500~1900GS ...
-
-
16.Motorcycle Starter Relay
Available Model: 50cc,60cc,70cc etc.low control current requested, which is less than 1A and the range for contact current is 30A to 60A Good function on water-proof.
-
-
17.DY100 series Ignition Coil
1. Primary resistance: 0.31Ω±15%, secondary resistance: 4.2Ω±15%. 2. When primary input 200V, the secondary voltage ≥23KV 3. When primary input 350V, the secondary voltage ≥35KV 4. Its capacitor closed magnetic circuit ignition coil. 5.Available model: Dayang, 70, 90
-
-
18.XH90 Ignition Coil
Capacitor Discharge Ignition, Unit of Ignition Coil and Ignitor and Strong Output. Fited on Ignitor and Ignition Coil. No interfere between Ignition Coil and Ignitor. Good insulation characteristics and high voltage withstand make the efficiency energy transmission. Good function on ignition whether high speed or low speed. Different situation can ...
-
-
19.3-5KW Range Generator Regulator
3-5KW Range Regulator Operating Condition `1. Operating Temperature Range: (-20~80)℃ 2. Storage Temperature Range: (-40~100)℃ 3. Factory set: 25℃±5℃ Electric Index 1. Voltage: 230±2V 2. Voltage Steady Range: ±1V 3. Starting Excitation Voltage: ≥1.5V 4. Loading Capacity: With 110% loading, the regulator can work no...
-
-
20.5.5-7KW Range Generator Regulator
5.5-7KW Range Regulator Operating Condition 1. Operating Temperature Range: (-20~80)℃ 2. Storage Temperature Range: (-40~100)℃ 3. Factory set: 25℃±5℃ Electric Index 1. Voltage: 230±2V 2. Voltage Steady Range: ±1V 3. Starting Excitation Voltage: ≥1.5V 4. L...